HTML has links - PDF has Authentication
51-11R-30310  <<  51-11R-30311 >>   51-11R-30312

PDFWAC 51-11R-30311

Table R303.1.3(1)Default glazed fenestration U-factor.

TABLE R303.1.3(1)
DEFAULT GLAZED WINDOW, GLASS DOOR AND SKYLIGHT U-FACTOR
FRAME TYPE
SINGLE PANE
DOUBLE PANE
 
Metal
1.20
0.80
SKYLIGHT
Metal with Thermal Breaka
1.10
0.65
See Table R303.1.3(4)
Nonmetal or Metal Clad
0.95
0.55
 
Glazed Block
0.60
a
Metal Thermal Break = A metal thermal break framed window shall incorporate the following minimum design characteristics:
 
1) The thermal conductivity of the thermal break material shall be not more than 3.6 Btu-in/h/ft2/°F;
 
2) The thermal break material must produce a gap in the frame material of not less than 0.210 inches; and
 
3) All metal framing members of the products exposed to interior and exterior air shall incorporate a thermal break meeting the criteria in 1) and 2) above.
[Statutory Authority: RCW 19.27A.045 and chapter 19.27A RCW. WSR 20-21-081, § 51-11R-30311, filed 10/19/20, effective 2/1/21. Statutory Authority: RCW 19.27A.020, 19.27A.045, 19.27A.160 and chapter 19.27 RCW. WSR 20-01-047, § 51-11R-30311, filed 12/9/19, effective 7/1/20. Statutory Authority: RCW 19.27A.020, 19.27A.045 and chapters 19.27 and 34.05 RCW. WSR 13-04-055, § 51-11R-30311, filed 2/1/13, effective 7/1/13.]
Site Contents