HTML has links - PDF has Authentication
296-24-69005  <<  296-24-69007 >>   296-24-69009

PDFWAC 296-24-69007

Flash welding equipment.

(1) Ventilation and flash guard. Flash welding machines must be equipped with a hood to control flying flash. In cases of high production, where materials may contain a film of oil and where toxic elements and metal fumes are given off, you must provide ventilation in accordance with WAC 296-24-71501 through 296-24-71525.
(2) Fire curtains. For the protection of the operators of nearby equipment, you must set up fire-resistant curtains or suitable shields around the machine and in such a manner that the operator's movements are not hampered.
(3) If the welding process cannot be isolated, you must properly protect all persons who may be exposed to the hazard of arc flash.
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, and 49.17.060. WSR 15-24-100, § 296-24-69007, filed 12/1/15, effective 1/5/16; Order 74-27, § 296-24-69007, filed 5/7/74; Order 73-5, § 296-24-69007, filed 5/9/73 and Order 73-4, § 296-24-69007, filed 5/7/73.]
Site Contents
Selected content listed in alphabetical order under each group