HTML has links - PDF has Authentication
296-96-05100  <<  296-96-05120 >>   296-96-05140

PDFWAC 296-96-05120

Operating devices, terminal stopping devices and electrical protective devices.

If electrically operated, such devices shall be enclosed. On lifts driven by winding drum machines, there shall be a slack rope device employing an enclosed electric switch (manually reset type) which removes power to the drum and brake when the hoisting rope becomes slack.
On other lifts suspended by flexible means such as chain, there shall be a slack rope/chains device employing an enclosed electric switch (manually reset type) which removes power to the machine and brake when the suspension means becomes slack.
[Statutory Authority: Chapter 70.87 RCW. WSR 18-18-070, § 296-96-05120, filed 8/31/18, effective 10/1/18; WSR 07-24-041, § 296-96-05120, filed 11/30/07, effective 1/1/08. Statutory Authority: RCW 70.87.020, 70.87.030, 70.87.034, 70.87.120, 70.87.185 and chapter 70.87 RCW. WSR 01-02-026, § 296-96-05120, filed 12/22/00, effective 1/22/01.]
Site Contents
Selected content listed in alphabetical order under each group