HTML has links - PDF has Authentication
51-11C-71031  <<  51-11C-71032 >>   51-11C-71033

PDFWAC 51-11C-71032

Table B103(2)—Health occupancy.

Table B103(2)
Health Occupancya
 
Schedule for Occupancy
Schedule for Lightingb/
Receptacle
 
Schedule for Service
Hot Water
Schedule for Elevator
Hour of Day
(time)
Percent of
Maximum Load
Percent of
Maximum Load
Schedule for HVAC System
Percent of
Maximum Load
Percent of
Maximum Load
 
Wk
Sat
Sun
Wk
Sat
Sun
Wk
Sat
Sun
Wk
Sat
Sun
Wk
Sat
Sun
1
(12-1am)
0
0
0
10
10
5
On
On
On
1
1
1
0
0
0
2
(1-2am)
0
0
0
10
10
5
On
On
On
1
1
1
0
0
0
3
(2-3am)
0
0
0
10
10
5
On
On
On
1
1
1
0
0
0
4
(3-4am)
0
0
0
10
10
5
On
On
On
1
1
1
0
0
0
5
(4-5am)
0
0
0
10
10
5
On
On
On
1
1
1
0
0
0
6
(5-6am)
0
0
0
10
10
5
On
On
On
1
1
1
0
0
0
7
(6-7am)
0
0
0
10
10
5
On
On
On
1
1
1
0
0
0
8
(7-8am)
10
10
0
45/50
20
5
On
On
On
17
1
1
2
2
0
9
(8-9am)
50
30
5
80/90
35/40
10
On
On
On
58
20
1
75
46
2
10
(9-10am)
80
40
5
80/90
35/40
10
On
On
On
66
28
1
100
70
2
11
(10-11am)
80
40
5
80/90
35/40
10
On
On
On
78
30
1
100
70
2
12
(11-12pm)
80
40
5
80/90
35/40
10
On
On
On
82
30
1
100
70
2
13
(12-1pm)
80
40
5
80/90
35/40
10
On
On
On
71
24
1
75
51
2
14
(1-2pm)
80
40
5
80/90
35/40
10
On
On
On
82
24
1
100
51
2
15
(2-3pm)
80
40
5
80/90
35/40
10
On
On
On
78
23
1
100
51
2
16
(3-4pm)
80
40
5
80/90
35/40
10
On
On
On
74
23
1
100
51
2
17
(4-5pm)
80
40
0
30
35/40
5
On
On
On
63
23
1
100
51
0
18
(5-6pm)
50
10
0
30
35/40
5
On
On
On
41
10
1
100
25
0
19
(6-7pm)
30
10
0
30
10
5
On
On
On
18
1
1
52
2
0
20
(7-8pm)
30
0
0
30
10
5
On
On
On
18
1
1
52
0
0
21
(8-9pm)
20
0
0
30
10
5
On
On
On
18
1
1
52
0
0
22
(9-10pm)
20
0
0
30
10
5
On
On
On
10
1
1
28
0
0
23
(10-11pm)
0
0
0
30
10
5
On
On
On
1
1
1
0
0
0
24
(11-12am)
0
0
0
10
10
5
On
On
On
1
1
1
0
0
0
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Total/Day
850
380
40
975/1060
500/550
160
2400
2400
2400
783
249
24
1136
540
16
Total/Week
 
46.70
hours
 
55.35/60.10
hours
 
168
hours
 
41.88
hours
 
62.36
hours
Total/Year
 
2435
hours
 
2878/3134
hours
 
8760
hours
 
2148
hours
 
3251
hours
Wk
= Weekday
a
Schedules for occupancy, lighting, receptacle, HVAC system, and service hot water are from ASHRAE Standard 90.1-1989 and addendums, except that 5 percent emergency lighting has been added for all off hours. Elevator schedules, except for restaurants, are from the U.S. Department of Energy Standard Evaluation Techniques except changed to 0 percent when occupancy is 0 percent. These values may be used only if actual schedules are not known.
b
Lighting profiles are modified to reflect the requirement for occupancy sensors in Section C405.2.
[Statutory Authority: RCW 19.27A.020, 19.27A.025 and chapters 19.27 and 34.05 RCW. WSR 13-04-056, § 51-11C-71032, filed 2/1/13, effective 7/1/13.]
Site Contents
Selected content listed in alphabetical order under each group