HTML has links - PDF has Authentication
296-304-16021  <<  296-304-16023 >>   296-304-16025

PDFWAC 296-304-16023

Limitations on use of wire rope.

(1) An eye splice made in any wire rope must have at least three tucks with a whole strand of rope and two tucks with one-half of the wires cut out of each strand. However, this requirement must not operate to preclude the use of another form of splice or connection which can be shown to be as efficient.
(2) Except for eye splices in the ends of wires, each wire rope used in hoisting or lowering, in guying derricks, or as a topping lift, preventer or pendant, must consist of one continuous piece without knot or splice.
(3) Eyes in the ends of wire rope cargo falls must not be formed by knots and, in single part falls, must not be formed by wire rope clips.
(4) The ends of falls must be secured to the winch drums by clamps, U-bolts, shackles or some other equally strong method. Fiber rope fastenings must not be used.
(5) Wire rope must not be used for the vessel's cargo gear if in any length of eight diameters, the total number of visible broken wires exceeds 10 percent of the total number of wires, or if the rope shows other signs of excessive wear, corrosion, or defect. Particular attention must be given to the condition of those sections of wire rope adjacent to any terminal connections, those sections exposed to abnormal wear, and those sections not normally exposed for examination.
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, and 49.17.060. WSR 17-18-075, § 296-304-16023, filed 9/5/17, effective 10/6/17; Order 74-25, § 296-304-16023, filed 5/7/74.]
Site Contents