HTML has links - PDF has Authentication
296-304-08001  <<  296-304-08003 >>   296-304-08005

PDFWAC 296-304-08003

Portable electric tools.

(1) The frames of portable electric tools and appliances, except double insulated tools approved by Underwriters' Laboratories, must be grounded either through a third wire in the cable containing the circuit conductors or through a separate wire which is grounded at the source of the current.
(2) Grounding circuits, other than by means of the structure of the vessel on which the tool is being used, must be checked to ensure that the circuit between the ground and the grounded power conductor has resistance which is low enough to permit sufficient current to flow to cause the fuse or circuit breaker to interrupt the current.
(3) Portable electric tools which are held in the hand must be equipped with switches of a type which must be manually held in the closed position.
(4) Worn or frayed electric cables must not be used.
(5) You must notify the officer in charge of the vessel before using electric power tools operated with the vessel's current.
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, and 49.17.060. WSR 17-18-075, § 296-304-08003, filed 9/5/17, effective 10/6/17; Order 74-25, § 296-304-08003, filed 5/7/74.]